Line 13: Line 13:
  
 Before the event, teams should identify and test with a switch the circuit that will be wired through the shutdown relay. Before the event, teams should identify and test with a switch the circuit that will be wired through the shutdown relay.
 +
 +The maxumum current flowing through the Relais must not exceede 2 Ampere
 +
  
 ===== ICE ===== ===== ICE =====
  
-  * The shutdown relay must kill the engine when the relay is activated. +The shutdown relay must kill the engine when the relay is activated. 
-  Connections can made be from N to NC (Normally Closed, will open when relay is activated) or from N to NO (Normally Open, will close when relay is activated) depending on system configuration + 
-  **Maximum current = amps**+ 
 +Connections can made be from N to NC (Normally Closed, will open when relay is activated) or from N to NO (Normally Open, will close when relay is activated) depending on system configuration 
 + 
 + 
 +**Maximum current = amps** \\ 
 +**Maximum voltage = 24 volt** \\ 
  
  
Line 30: Line 39:
 {{ :student_documentation:Shutdown_Relay_ICE.JPG?nolink&400 |}} {{ :student_documentation:Shutdown_Relay_ICE.JPG?nolink&400 |}}
  
-THE SHUTDOWN RELAY MUST NOT BE CONNECTED TO THE IGNITION COIL OR E-STOP+THE SHUTDOWN RELAY MUST NOT BE CONNECTED TO THE IGNITION COIL. 
  
  
Line 36: Line 45:
  
 The shutdown relay must disable vehicle propulsion when the relay is activated. The shutdown relay must disable vehicle propulsion when the relay is activated.
 +
 +
 Connections can be made from N to NC (Normally Closed, will open when relay is activated) or from N to NO (Normally Open, will close when relay is activated) depending on system configuration. Connections can be made from N to NC (Normally Closed, will open when relay is activated) or from N to NO (Normally Open, will close when relay is activated) depending on system configuration.
-Maximum relay current = amps. + 
-  + 
 +**Maximum current = amps** \\ 
 +**Maximum voltage = 24 volt** \\ 
   * Option 1 - disables motor control when activated   * Option 1 - disables motor control when activated
     * NC contacts on motor controller on/off     * NC contacts on motor controller on/off