User Tools

Site Tools


telemetry_data:channel_descriptions

This is an old revision of the document!


Channel Descriptions

These data sets include measured data from the sensors, derived values using measured data, and data resulting from modeling. Modeling is necessary to better understand and to make better use of the measured data.

Channel Name Format or units Example Data Group Description
obc_timeStamp UNIX epoch time 1665563504 OBC Timestamp from operating system of on-board computer.
gps_utcTime HH.mm.ss 18.44.17 GPS Timestamp from GPS sensor. Updates once per second.
gps_latitude decimal degrees 42.327805 GPS Latitude position from GPS.
gps_longitude decimal degrees -83.048379 GPS Longitude position from GPS.
gps_fixQuality none 1 GPS Quality of location values from GPS.
gps_dilution none 0.8 GPS Strength of GPS signal.
gps_speed km/h 10.9 GPS Vehicle speed from GPS. Updates once per second.
jm3_netJoule J 5482 JM Net Joules measured by Joule Meter.
jm3_voltage mV 12353 JM Instantaneous voltage measured by Joule Meter.
jm3_current mA 12342 JM Instantaneous current measured by Joule Meter.
lfm_netCounts none 389 LFM Pulses from Liquid Flow Meter indicating total flow rate, taking into account negative flow.
lfm_posCounts none 411 LFM Pulses from Liquid Flow Meter indicating positive flow rate.
lfm_temperature °C 18.1 LFM Temperature of fuel measured by Liquid Flow Meter.
lfm_integratedCorrFlow ml 6.4468 LFM Volume of fuel consumed since last reset measured by Liquid Flow Meter.
lfm_instantFlow ml/min 19.0278 LFM Instantaneous flow rate of fuel measured by Liquid Flow Meter.
gfs_gasFlow m^3/min GFS Instantaneous flow rate of gas measured by Gas Flow Sensor.
gfs_gasTemp °C GFS Temperature of gas measured by Gas Flow Sensor.
gfs_netGasVolume m^3 GFS Volume of gas consumed since last reset measured by Gas Flow Sensor.
sup_VoltageIn mV 14800 SUP OBC supply voltage.
all_energy ml for ICE, l for Hydrogen, and J for Battery Electric 14800 ALL Total cumulative energy consumption including starter or accessory battery (see Chapter I Rules Article 54).
volt_voltage mV 14800 VOLT Current Supercap voltage reading.
volt_difference mV 14800 VOLT Difference in Supercap voltage since reset.
Lap Number 0 Post GPS Lap counter based on GPS position (subject to GPS strength).
This website uses cookies. By using the website, you agree with storing cookies on your computer. Also you acknowledge that you have read and understand our Privacy Policy. If you do not agree leave the website.More information about cookies